—— Wira
The spring impact hammer applies a defined mechanical energy to an enclosure. The test looks simple and is easy to invalidate: the wrong energy, a hammer held at an angle, or a strike point chosen for convenience rather than for weakness will all produce a result that cannot be repeated.
IEC 60068-2-75 defines a family of hammers with nominal energies of 0.14, 0.2, 0.35, 0.5, 0.7, 1.0 and 2.0 joules. The product standard selects the energy and the number of impacts. IK ratings map to impact energy, so an IK08 test is not a generic "hit it hard" test; it is a specific energy applied in a specific way.
| Small, light enclosure | Low energy, but more strike points; thin walls fail locally. |
| Floor-standing cabinet | Higher energy at the most exposed face and at the edges. |
| Window or display | Strike at the centre and near a fixing, where the pane is least supported. |
The hammer is cocked, placed perpendicular to the surface, and released. The energy delivered depends on the release mechanism working freely and on the hammer being perpendicular at the moment of release. Practical points:
The standard requires the points most likely to cause a hazard, not the most convenient flat area. A defensible set includes:
Mark the points on a photograph before testing. After the test, the photograph is the only evidence that the required points were actually struck.
The pass criteria come from the product standard and normally combine three checks: no exposure of live parts, no damage that reduces creepage or clearance below the required value, and continued function. A cracked moulding that still works may still fail the second check. Inspect with the enclosure open, using the same access probes the safety standard requires, and repeat the dielectric test where the standard calls for it.
A spring hammer is a mechanical device with a spring, a latch and a nose. All three wear. Calibration should verify the released energy, not just that the hammer fires. A simple verification is a pendulum or a velocity measurement; the certificate should state the measured energy at each setting. A hammer that has lost 10 % of its energy passes enclosures that should have failed, and nothing on the enclosure tells you.
For each test record: hammer identification and calibration date, energy setting, number of impacts, strike point coordinates, enclosure support, result at each point, and photographs before and after. The test equipment range includes spring impact hammers and the accessory anvils and supports that make the setup repeatable; the news section carries further notes on enclosure testing.
IEC60061-3 E27 Lamp cap go gauge and no go gauges