Impact Energy: Which Hammer Actually Delivers Your IK Level

IK ratings are quoted as a number of joules, which makes them look like a single continuous scale. They are not. The instrument that delivers 0.5 J is not the instrument that delivers 20 J, and the boundary between them sits exactly where most product specifications start to matter.

The spring hammer's range

The spring-operated impact hammer described in IEC 60068-2-75 is made in a discrete set of energies: 0.14 J, 0.2 J, 0.35 J, 0.5 J, 0.7 J, 1 J and 2 J. That is the whole family. There is no 5 J spring hammer in the standard, and a "5 J spring hammer" offered for sale is either a different instrument or a mislabelled one.

Mapped onto IK levels, the spring hammer covers IK01 through IK07:

IK levelEnergyUsual instrument
IK01 – IK060.14 J – 1 Jspring hammer
IK072 Jspring hammer (largest)
IK085 Jpendulum hammer or drop ball
IK09 – IK1010 J – 20 Jpendulum hammer or drop ball

The consequence is practical: a test plan that says "impact, IK08, spring hammer" cannot be executed as written. Either the level or the instrument has to change.

Why energy is not the whole story

Two instruments delivering the same energy do not produce the same damage. What matters is how the energy is delivered — the mass, the velocity and the contact geometry.

The 2 J spring hammer delivers its energy through a 0.5 kg striker over a contact time measured in fractions of a millisecond, on a hemispherical striking face. The peak force is high and the duration short.

The 5 J pendulum delivers five joules from a larger mass swinging through a longer arc, with a contact time an order of magnitude longer. The same enclosure can survive the spring hammer and crack under the pendulum, because the pendulum gives the material time to deflect.

This is why the standard specifies the instrument and not just the energy. Substituting one for the other and calling it "5 J either way" is not a valid substitution.

The setup details that change the result

Sample support. An enclosure resting on a rigid steel block behaves differently from the same enclosure held in a fixture. The standard requires the sample to be supported in its normal mounting arrangement, and a rigid or resilient backing changes how much energy the sample absorbs.

Strike point. Weak points are corners, edges and the centre of large flat panels. Testing only the centre of a panel gives an optimistic result, because the panel flexes and the corner does not.

Number of strikes. One strike per point is the minimum. Where the standard requires five, the fifth strike is often on a surface that has already been weakened by the first four — which is the point.

Conditioning. Plastics at 5 °C behave very differently from plastics at 23 °C. If the product standard specifies conditioning, the impact must happen within the time window after removal, not an hour later.

What a defensible IK test record contains

Instrument type and energy, strike points with a photograph of each, sample support description, conditioning temperature and time since removal, and the acceptance criterion with the observed result. Without the instrument type, "IK07 passed" cannot be distinguished from "IK07 passed with the wrong hammer" — which is the same problem as not testing at all.