IK Pendulum or Spring Hammer: Choosing the Impact Source for the Enclosure

The IK code describes an enclosure's resistance to mechanical impact. The code is a number from 00 to 10, and behind each number is an energy in joules. What the code does not state is the instrument, and that is where two laboratories can disagree: a 5 J spring hammer strike and a 5 J pendulum strike are not the same event.

The energy ladder and its codes

IK codeIK00IK01IK02IK03IK04IK05
Energynone0.14 J0.2 J0.35 J0.5 J0.7 J
IK codeIK06IK07IK08IK09IK10
Energy1 J2 J5 J10 J20 J

IK00 means no protection is claimed. IK10 at 20 J is the top of the ladder and is a serious enclosure: a 5 kg mass dropped from 400 mm is 19.6 J, which is the order of energy involved.

Three sources, three pulses

  • Spring hammer. Stores energy in a spring, releases it through a small head. The pulse is short and the contact area is small, so the local pressure is high. Good for thin walls, covers and small features.
  • Pendulum hammer. A swinging mass with a defined head radius. The pulse is longer, the contact area larger, and the energy is transferred over more of the surface. Good for flat panels and large enclosures.
  • Free-fall ball or drop test. A mass dropped from a height. The pulse depends on the surface it lands on and on the rebound, and the contact is a sphere. Good for horizontal surfaces and for simulating a dropped tool.

The same energy through a small head and through a large head produces different local stress. A 5 J spring hammer strike can crack a 1.5 mm wall that a 5 J pendulum strike would dent only slightly.

Choosing the method the standard expects

The product standard states the method, and where it does not, the enclosure geometry decides:

  1. Read the product standard first. It will name the instrument or the relevant part of IEC 62262.
  2. Match the head to the feature being tested. Small features and thin walls take the spring hammer; large flat panels take the pendulum.
  3. Test the weakest points, identified by inspection, not evenly distributed points.
  4. Test in the mounted condition, with the mounting the product will have in service.

Reading the result

Acceptance is functional, not cosmetic. The usual criteria: no damage that impairs safety, no live part made accessible, no reduction of creepage and clearance below the product standard's values, and the enclosure still meets its IP rating.

The last criterion is the one that catches people. A crack that does not expose anything can still destroy an IP65 rating, and the IP test is the only way to know. Three findings, recorded separately:

  • Penetration — the head has gone through the wall. Almost always a fail.
  • Crack with displacement — the wall is split and the two sides have moved relative to each other. A fail if it affects sealing or clearance.
  • Dent without cracking — deformation with no separation. A pass unless a clearance is reduced below the required value, which has to be measured.

Verification of the instrument

An impact instrument is a stored-energy device, and the energy it delivers is not automatically the energy on its label. Spring hammers are verified against a force transducer or a reference anvil; pendulums are verified by geometry (mass, arm length, release height) and by the head radius. Both should be checked at intervals short enough that a drifting instrument is caught before a batch of results is invalidated.

The impact testing range covers spring hammers and pendulum apparatus across the IK ladder; the catalogue home indexes the mounting jigs that keep the test condition repeatable.