Of all the glow-wire temperatures in use, 960 degrees C produces the most discussion and the least agreement. It is the highest temperature in common use under IEC 60695-2-10, it appears in product standards for parts that must not propagate fire, and it has two failure modes that are recorded separately and often collapsed into one.
The glow-wire temperatures form a short list, and product standards pick from it according to how the part is used:
| 550 degrees C | Parts that may be touched and are not near a heat source |
| 650 degrees C | Parts that may be touched, with a modest thermal load |
| 750 degrees C | Parts that hold current-carrying connections |
| 850 degrees C | Parts near a source of ignition |
| 960 degrees C | Parts that must contain a fire, or unattended appliances where the consequence of fire is severe |
960 is not "the strictest test" in an absolute sense; it is the temperature applied where the consequence of failure justifies it. Applying it to a part the product standard tests at 650 is not a better test, it is a test the part was never designed for.
The loop is brought to temperature and held for at least 60 s, then applied to the specimen for 30 s with a force of 1 N. The specimen is mounted as in service, with the tissue paper positioned below at the distance the method specifies.
Three details decide whether the application is the specified one:
This is the point most reports miss. A specimen fails in one of two ways, and they are not equivalent:
A material can have an excellent afterflame performance and a poor droplet behaviour, and the droplet behaviour is often the more relevant one in an enclosure with a wiring harness below the part.
The tissue paper is not decoration. It is the detector for mode two, and three things affect whether it works:
Five items, in this order: test temperature, application time, time to extinguish after withdrawal, whether the tissue paper ignited, and the post-test condition of the specimen including penetration depth and whether the part remains functional.
The last item is the one that turns a test result into an engineering finding. A part that passes both flame criteria but has a hole through a wall that carries a creepage path has failed in the sense that matters to the product standard, and that failure is invisible in the flame data.
The flammability test range includes glow-wire apparatus with calibrated force and temperature verification; the catalogue home indexes the specimen supports and tissue-paper jigs used with it.
IEC60061-3 E27 Lamp cap go gauge and no go gauges
IEC60061 B22 Go No Go Gauge of 7006-11-8 & 7006-10-8
Ipx3 Ipx4 Hand-Held Spray Nozzle
IEC 60529 Ingress Protection Test Probe Kit of Access Probes
Manufacture High Precision IEC60950 Telecom Test Probe