—— Wira
Of all the fire and heat tests, the ball pressure test has the fewest variables. A 5 mm steel ball, a 20 N load, a specified temperature, one hour, and a measurement of the resulting indentation. The judgement is a diameter, usually 2 mm. Everything that goes wrong with the test goes wrong in the choice of temperature, or in the preparation of the sample.
The temperatures are not material properties; they are consequences of the product. A part that is only accessible when the appliance is opened, and that is not near a heat source, is tested at the lower temperature. A part that supports a current-carrying connection, or that is in contact with a part that reaches a high temperature in normal use, is tested higher, because the material has to keep its shape while hot.
The number that drives the choice is the temperature rise measured on that part during the heating test, plus the ambient, plus a margin. A terminal block that reaches 95 °C in a 25 °C room is a 70 K rise, and if the standard requires the ball test at the temperature of the part plus a margin, the part belongs in the higher band, not the lower one.
| Part location | Measured temperature in normal use | Ball test temperature | Typical indentation limit |
| Enclosure, not near heat | 35 to 45 °C | 75 °C | 2 mm |
| Enclosure near a heat source | 55 to 70 °C | 75 °C, evaluate separately | 2 mm |
| Terminal block, current-carrying | 70 to 100 °C | 125 °C | 2 mm |
| Support of a live part | 80 to 110 °C | 125 °C | 2 mm |
| Part in contact with a heating element | Above 100 °C | Higher band, per product standard | 2 mm |
A ball pressure test on a 2 mm thick sample cut from a moulding reads differently from the same test on the finished part. The moulding has ribs, a flow pattern, and residual stress; a cut coupon has none of them. The standard asks for the part, or a representative section, and a coupon is only acceptable when the part is too small or too curved to test.
The sample must also be conditioned. A polyamide that has absorbed 2 % moisture softens at a lower temperature than the dry resin, and a test run on a sample straight from a humid store will show a larger indentation than one run after drying. If the material specification is for the dry state, dry the sample; if the part runs wet in service, that is the state to test, and it should be written down.
The measurement is the diameter of the impression left by the ball, measured with a travelling microscope or a profile projector, after the sample has cooled. Measuring while hot, or measuring the ball rather than the impression, are both common errors. The impression is not circular if the sample was not level, and an oval impression is a setup problem, not a material result.
A 2.1 mm indentation is a fail, and a 1.9 mm indentation is a pass, but the difference between them is often batch-to-batch variation rather than design. A part that measures 1.8 mm on one batch and 2.1 mm on the next has a process problem: regrind content, mould temperature, or insufficient drying. Looking at the trend over three lots is more informative than the individual verdict.
Standards referenced: IEC 60695-10-2 (ball pressure test), with the test temperature and the indentation limit taken from the relevant product standard (IEC 60335-1, IEC 61010-1, IEC 60598-1).
IEC60061-3 E27 Lamp cap go gauge and no go gauges
IEC60061 B22 Go No Go Gauge of 7006-11-8 & 7006-10-8
Ipx3 Ipx4 Hand-Held Spray Nozzle
IEC 60529 Ingress Protection Test Probe Kit of Access Probes
Manufacture High Precision IEC60950 Telecom Test Probe